Fiber kábel MPO-MPO, 10m Duplex OM4(50/125µm), LSOH, 4.5mm, Trunk Cable, fialový

Fiber kábel MPO-MPO, 10m Duplex OM4(50/125µm), LSOH, 4.5mm, Trunk Cable, fialový

Kód: {{ productModel }}
Výrobca: Value
Kat. č.: 21.99.1103-5
EAN: 7630049691827

MPO (multi-fibre push-on) kabelážny systém MPO (multi-fibre push-on) kabelážny systém j..... celý popis

Externý sklad 
128,23 € s DPH 106,86 € bez DPH
Konektory MPO-MPO
Typ kábla Duplex
Typ vlákna Multimod OM4(50/125µm) fialový
Dĺžka kábla 10m
Prevedenie kábla Trunk kábel ø4.5mm

MPO (multi-fibre push-on) kabelážny systém

MPO (multi-fibre push-on) kabelážny systém je ľahko použiteľné riešenie založené na vysokohustotnom konektore a plochých kábloch s 12 žilami. Tento systém sa bežne používa v dátových centrách ale aj napr. medzi serverovňami. Je navrhnutý pre spoľahlivé a rýchle operácie so zjavnými výhodami menšej požiadavky na priestor a lepšej škálovateľnosti. Vopred ukončené káble MPO sa môžu rozvetvovať na iné pripojenia, zvyčajne k LC, na prepojenie s produktmi alebo službami so štandardnou hustotou pomocou modulov alebo káblov s rozvetvením.

KĽÚČOVÉ FAKTY MPO

  • Plne podporuje všetky aplikácie s optickými vláknami v rámci rodiny Ethernet
  • Modulárne riešenie s opakovane použiteľnými modulmi a káblami
  • Kabeláž s vysokou hustotou šetrí priestor na ceste a poskytuje lepšie prúdenie vzduchu v porovnaní s tradičnými káblovými zväzkami
  • Káble sú vo výrobe vopred ukončené na správnu dĺžku s vysokou hustotou pripojenia

Konektory MPO sa zvyčajne dotýkajú 12 vlákien v jednom spojení. Spojenie musí byť stabilné a jeho konce musia byť správne zarovnané. Tieto aspekty sú nevyhnutné na dosiahnutie požadovaných parametrov prenosu.
Preto sú konektory MPO dostupné v prevedení samec (s kolíkmi) alebo samica (bez kolíkov). Kolíky zaisťujú, že čelá konektorov sú pri kontakte presne zarovnané a že konce vlákien nie sú odsadené. Poznámka: všetky káble neobsahujú halogény (LSOH). Konektory sú nízkostratové konektory s veľmi nízkym útlmom.

Pravidlá pripojenia
a) Pri vytváraní spojenia MPO vždy použite jeden konektor samec a jeden konektor samice plus jeden adaptér MPO.
b) Nikdy nespájajte samca so samcom alebo samicu so samicou. Pri spojení samica-samica nebudú jadrá vlákien dvoch konektorov v presne rovnakej výške, pretože chýbajú vodiace kolíky. To povedie k strate výkonu. Spojenie medzi mužom a mužom má ešte katastrofálnejšie výsledky. Tam vodiace kolíky narážajú na vodiace kolíky, takže nedochádza k žiadnemu kontaktu. To môže tiež poškodiť konektory.
c) Nikdy nerozoberajte konektor MPO. Kolíky sa ťažko odpájajú od konektora MPO a vlákna sa môžu pri tomto procese zlomiť.

MPO-12 TYP A (rovný) Key-Up až Key-Down

STRANA A: 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12

STRANA B: 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12

MPO-káble

Káble MPO sa dodávajú už ukončené. Vyžaduje si to väčšiu pozornosť pri plánovaní vopred, ale má to množstvo výhod: krátke montážne časy, odskúšaná a zaručená kvalita a veľká spoľahlivosť.

Kufrové káble: Kufrové káble slúžia ako trvalé prepojenie medzi modulmi MPO. Kufrové káble sú k dispozícii s 12 vláknami. Ich konce sú ukončené 12-vláknovými MPO konektormi v zásuvke (bez kolíkov).

Fan-Out káble: Fan-Out káble sa používajú na pripojenie MPO kábla ku konektorom štandardnej hustoty, zvyčajne k 12 LC konektorom.

Optické vlákno - Kábel OM4: Pozrite si prepojovací kábel z optických vlákien 50/125µm OM4 v našom katalógu. Kľúčovým bodom každej inštalácie je zabezpečiť správne zapojenie medzi vysielačom a prijímačom. V prípade použitia sady kaziet, trunkových káblov a duplexných patchcordov - je potrebné dodržať určité pravidlo pre metódu polarity trunkových káblov. Prípad popísaný na obrázku je podľa metódy polarity A, čo znamená, že duplexné prepojovacie káble z optických vlákien MUSIA byť na jednej strane KRÍŽNE zapojené a na druhej strane ROVNO.

MPO-Adaptéry

Adaptéry slúžia na pripojenie dvoch MPO konektorov. Presadzujú, že oba kľúče sú hore. Takže dva konektory sú spojené v rovnakej polohe voči sebe navzájom.

MPO-moduly

Moduly a adaptérové dosky sú to, čo spája trvalé spojenie s prepojovacím káblom so štandardnou hustotou. Modul MPO umožňuje užívateľovi zobrať vlákna privádzané kmeňovým káblom a distribuovať ich do duplexného kábla. Ako už zmontované jednotky, moduly MPO sú osadené 12 vláknami a majú LC adaptéry na prednej strane a MPO na zadnej strane. Moduly je možné zabudovať do panelov pre inštaláciu do 19" racku.

Technické špecifikácie

Skupina produktov Kábel z optických vlákien
Typ produktu MPO (nasadzovanie z viacerých vlákien)
Farba fialový
Dĺžka 10 m
Množstvo vlákniny 12
Zloženie vodiča Kompaktný vodič
Externý kábel nie
Vláknová sekcia 50/125 um OM4
Strana 1 Typ konektora MPO
Typ konektora na strane 2 MPO
Odľahčenie aramidového napätia Áno
Kábel LSOH Áno
Technická zvláštnosť MPO-12 TYP A (rovný) Key-Up až Key-Down
Hmotnosť 190,2 g

MPO (multi-fibre push-on) cabling system

The MPO (multi-fibre push-on) cabling system is an easy-to-use solution based on a high density connector and ribbon-fiber cables with 12 cores. This system is commonly used in data centers but also e.g. between server rooms. It is designed for reliable and quick operations with the obvious benefits of less space requirements and improved scalability. The pre-terminated MPO cables can fan-out to other connections, usually to LC, to interconnect with standard-density products or services, using modules or fan-out cables.

KEY FACTS MPO

  • Fully supports all optical fiber applications within the Ethernet family
  • Modular solution with reusable modules and cables
  • High-density cabling saves pathway space and gives improved airflow compared to traditional cable bundles
  • Cables are pre-terminated in the factory to the correct length with high density connectivity

MPO connectors contact usually 12 fibers in a single connection. A connection must be stable and its ends correctly aligned. These aspects are essential for achieving the required transmission parameters.
Therefore MPO connectors are available in a male version (with pins) or a female version (without pins). The pins ensure that the fronts of the connectors are exactly aligned on contact and that the end-faces of the fibers are not offset.Remark: all cables are halogen-free (LSOH). The connectors are low-loss connectors with a very low attenuation.

Connection rules
a) When creating an MPO connection, always use one male connector and one female connector plus one MPO adapter.
b) Never connect a male to a male or a female to a female. With a female-to-female connection, the fiber cores of the two connectors will not be at the exact same height because the guide pins are missing. That will lead to losses in performance.A male-to-male connection has even more disastrous results. There the guide pins hit against guide pins so no contact is established. This can also damage the connectors.
c) Never dismantle an MPO connector.The pins are difficult to detach from an MPO connector and the fibers might break in the process.

MPO-12 TYPE A (straight) Key-Up to Key-Down

SIDE A: 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12

SIDE B: 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12

MPO-Cables

MPO cables are delivered already terminated. That requires greater care in planning in advance but it has a number of advantages: short installation times, tested and guaranteed quality and great reliability.

Trunk cables: Trunk cables serve as a permanent link connecting the MPO modules to each other. Trunk cables are available with 12 fibers. Their ends are terminated with 12-fiber MPO connectors female version (without pins).

Fan-Out cables: Fan-Out cables are used for the connection of a MPO cable to standard-density connectors, usually to 12 LC connectors.

Fiber optic - Cable OM4: Please see Fiber optic jumper cable 50/125µm OM4 in our catalogue. The key point of each installation is to ensure the correct wiring from transceiver to receiver. In case of using a set of cassettes, trunkcables and duplex patchcords - you need to follow a certain guideline for the polarity method of the trunkcables. The case described in the graphic is according to the polarity A method, means the duplex fibre optic jumper cables MUST be CROSS connected on one side and STRAIGHT connected on the second side.

MPO-Adapters

Adapters are used to connect two MPO connectors. They enforce that both keys are up. So the two connectors are connected while in the same position in relation to each other.

MPO-Modules

Modules and adapter plates are what connect the permanent link to the standard-density patch cable. The MPO module enables the user to take the fibers brought by a trunk cable and distribute them to a duplex cable. As already assembled units, the MPO modules are fitted with 12 fibers and have LC adapters on the front side and MPO at the rear. The modules can be built in panels to be installed in a 19" rack.

Technical specifications

Product groupFibre optic cable
Product typeMPO (multi-fibre push-on)
Colourviolet
Length10 m
Quantity of fibre12
Conductor compositionCompact conductor
External cableno
Fibre sectionMulti mode 50/125µm OM4
Side 1 Connector TypeMPO
Side 2 Connector TypeMPO
Aramid strain reliefyes
Cable LSOHyes
Technical particularityMPO-12 TYPE A (straight) Key-Up to Key-Down
Weight190.2 g
Height of packaging (single piece)30 mm
Width of packaging (single piece)220 mm
Depth of packaging (single piece)220 mm
Package weight (single piece)0.3 kg
Gross weight0.3
Parametre
Konektory
MPO-MPO
Typ kábla
Duplex
Typ vlákna
Multimod OM4(50/125µm) fialový
Dĺžka kábla
10m
Prevedenie kábla
Trunk kábel ø4.5mm
LSOH
Áno
Prevedenie konektora
Štandardné
Prečo my
Extra rýchla doprava

V Bratislave vám tovar doručíme do 2 hodín a do iných miest Slovenska do 24 hodín.

8 000 + produktov

Na sklade reálne držíme skoro 8000 produktov, ktoré sú ihneď k dispozícií k odoslaniu.

Riešenia na mieru

Ak zariadujete nové priestory, alebo kanceláriu vieme vám zabezpečiť kompletné riešenie.